The American Journal of Psychiatry
Journal Home Search Current Issue Past Issues Subscribe All APPI Journals Help Contact Us
 
Quicksearch
Advanced Search
Or Search All APPI Journals
This Article
* Full Text (PDF)
* Alert me when this article is cited
* Alert me if a correction is posted
Services
* Email this article to a Colleague
* Similar articles in this journal
* Similar articles in PubMed
* Alert me to new issues of the journal
* Add to My Articles & Searches
* Download to citation manager
* reprints & permissions
Citing Articles
* Citing Articles via Google Scholar
Google Scholar
* Articles by SWARTZ, C. M.
* Search for Related Content
PubMed
* PubMed Citation
* Articles by SWARTZ, C. M.
Related Collections
* ECT
Am J Psychiatry 158:973-974, June 2001
© 2001 American Psychiatric Association


Letter to the Editor

ECT Failure Rate Among Specific Devices

CONRAD M. SWARTZ, PH.D., M.D.
Springfield, Ill.

To the Editor: In reporting that adequate ECT seizures were not obtained at the maximum electrical stimulus dose in 5% of ECT patients, Andrew D. Krystal, M.D., M.S., et al. (1) did not recognize that this result is limited to the MECTA Corporation ECT device they used. Instead, they suggested that their results apply to all devices: "Approximately one of six patients...required the maximum possible ECT stimulus intensity available on U.S. ECT devices" (p. 965). The result is limited to MECTA devices because the pulse width and frequency of the maximum stimulus they use are specific to MECTA devices, and their values are crucial to the reported study. These values are for a 2.0-msec pulse width and a 90-Hz frequency with a 2.0-sec duration and 0.8 A current. Compared to these values, the combination of a narrower pulse width, lower frequency, and longer duration should produce lower rates of failure for seizure induction (2, 3). The point that a 5% failure rate is needlessly high is indisputable. However, the failure rate should be substantially lower with more efficient electrical stimuli as well as with higher doses.

Dr. Krystal et al. repeatedly noted a "maximum stimulus intensity limitation of 576 millicoulombs (mC) imposed on U.S. ECT devices by the Food and Drug Administration (FDA)" (p. 963). The actual limitation is 100 J of energy at 220 {Omega} of impedance. For 0.8 A current, as used in MECTA devices, this limitation corresponds to 572 mC. The original source for a figure of 576 mC is MECTA’s commercial literature. I also wish to point out that nowhere in their published article do Dr. Krystal et al. note their relationship with MECTA Corporation.

Footnotes

The author is a member/manager of Somatics LLC, a maker of ECT instruments.

References

  1. Krystal AD, Dean MD, Weiner RD, Tramontozzi LA III, Connor KM, Lindahl VH, Massie RW: ECT stimulus intensity: are present ECT devices too limited? Am J Psychiatry 2000; 157:963–967[Abstract/Free Full Text]
  2. Swartz CM, Larson G: ECT stimulus duration and its efficacy. Ann Clin Psychiatry 1989; 1:147–152
  3. Swartz CM, Manly DT: Efficiency of the stimulus characteristics of ECT. Am J Psychiatry 2000; 157:1504–1506




This Article
* Full Text (PDF)
* Alert me when this article is cited
* Alert me if a correction is posted
Services
* Email this article to a Colleague
* Similar articles in this journal
* Similar articles in PubMed
* Alert me to new issues of the journal
* Add to My Articles & Searches
* Download to citation manager
* reprints & permissions
Citing Articles
* Citing Articles via Google Scholar
Google Scholar
* Articles by SWARTZ, C. M.
* Search for Related Content
PubMed
* PubMed Citation
* Articles by SWARTZ, C. M.
Related Collections
* ECT


Get information about faster international access.

Privacy Policy

Copyright © 2001 American Psychiatric Association. All rights reserved.

Home | Search | Current Issue | Past Issues | Subscribe | All APPI Journals | Help | Contact Us

American Psychiatric Publishing, Inc. American Psychiatric Association
1000 Wilson Boulevard, Suite 1825, Arlington, VA 22209-3901 * 800-368-5777 * appi at psych.org